{"product_id":"lk-mn-2-thermal-overload-relay-3-5a","title":"LK (L\u0026T) MN2 Overload Relay 3-5A, for MNX 9-40","description":"\u003cdiv class=\"vk-rich\" style=\"font-size:15px;line-height:1.7;color:#374151\"\u003e\n\u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003eLK (L\u0026amp;T) MN2 thermal overload relay, 3-5 A\u003c\/strong\u003e, for direct mounting on MNX 9-40 contactors. It protects a motor against overload and single phasing, and is ambient temperature compensated. Ratings are from Lauritz Knudsen's own product data.\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;color:#111827;margin:28px 0 12px;padding-left:10px;border-left:4px solid #D97706;line-height:1.3\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #E2E8F0;border-radius:10px;margin:0 0 4px\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:0;font-size:14px\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#F8FAFC\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eLauritz Knudsen (LK), formerly L\u0026amp;T Switchgear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eMN 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F8FAFC\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eCatalogue number\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eSS94141OOSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eAdjustment range\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003e3-5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F8FAFC\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eTrip class\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eClass 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003e415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F8FAFC\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eDirect mounting on MNX 9-40 contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eControls\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eStart and OFF \/ reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F8FAFC\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eAmbient temperature compensated, with single phasing protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff\"\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;width:34%;font-weight:600;color:#111827;vertical-align:top\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:0;border-bottom:1px solid #E2E8F0;vertical-align:top\"\u003eIS\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0\"\u003e\u003ca href=\"https:\/\/www.lk-ea.com\/cn\/SS94141OOSO\" target=\"_blank\" rel=\"noopener\" style=\"color:#B45309;font-weight:600;text-decoration:underline\"\u003eSS94141OOSO on Lauritz Knudsen's site\u003c\/a\u003e · \u003ca href=\"\/collections\/l-t\" style=\"color:#B45309;font-weight:600;text-decoration:underline\"\u003eAll MN2 ranges and MNX contactors\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 style=\"font-size:17px;font-weight:700;color:#111827;margin:28px 0 12px;padding-left:10px;border-left:4px solid #D97706;line-height:1.3\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails class=\"vk-faq-item\" style=\"border:1px solid #E2E8F0;border-radius:10px;margin:0 0 8px;background:#fff\"\u003e\u003csummary class=\"vk-faq-q\" style=\"cursor:pointer;font-weight:600;color:#111827;padding:12px 14px;font-size:15px;line-height:1.4\"\u003eWhat is the setting range of this MN2 relay?\u003c\/summary\u003e\u003cdiv class=\"vk-faq-a\" style=\"padding:0 14px 14px;font-size:14px;color:#374151\"\u003e3-5 A. Set the dial to your motor's full-load current from its nameplate, and choose a range where that current falls inside it.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"vk-faq-item\" style=\"border:1px solid #E2E8F0;border-radius:10px;margin:0 0 8px;background:#fff\"\u003e\u003csummary class=\"vk-faq-q\" style=\"cursor:pointer;font-weight:600;color:#111827;padding:12px 14px;font-size:15px;line-height:1.4\"\u003eWhich contactors does the MN2 overload relay fit?\u003c\/summary\u003e\u003cdiv class=\"vk-faq-a\" style=\"padding:0 14px 14px;font-size:14px;color:#374151\"\u003eThe MN 2 mounts directly on \u003ca href=\"\/collections\/l-t\" style=\"color:#B45309;font-weight:600;text-decoration:underline\"\u003eMNX 9 to MNX 40 contactors\u003c\/a\u003e.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"vk-faq-item\" style=\"border:1px solid #E2E8F0;border-radius:10px;margin:0 0 8px;background:#fff\"\u003e\u003csummary class=\"vk-faq-q\" style=\"cursor:pointer;font-weight:600;color:#111827;padding:12px 14px;font-size:15px;line-height:1.4\"\u003eIs this L\u0026amp;T or Lauritz Knudsen?\u003c\/summary\u003e\u003cdiv class=\"vk-faq-a\" style=\"padding:0 14px 14px;font-size:14px;color:#374151\"\u003eL\u0026amp;T Switchgear became Lauritz Knudsen (LK) in 2024, so this is the same MN relay range under the LK name. Units may carry either name depending on stock.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"vk-faq-item\" style=\"border:1px solid #E2E8F0;border-radius:10px;margin:0 0 8px;background:#fff\"\u003e\u003csummary class=\"vk-faq-q\" style=\"cursor:pointer;font-weight:600;color:#111827;padding:12px 14px;font-size:15px;line-height:1.4\"\u003eDo you provide a GST invoice?\u003c\/summary\u003e\u003cdiv class=\"vk-faq-a\" style=\"padding:0 14px 14px;font-size:14px;color:#374151\"\u003eYes. Every order comes with a GST invoice.\u003c\/div\u003e\u003c\/details\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the setting range of this MN2 relay?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"3-5 A. Set the dial to your motor's full-load current from its nameplate, and choose a range where that current falls inside it.\"}}, {\"@type\": \"Question\", \"name\": \"Which contactors does the MN2 overload relay fit?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The MN 2 mounts directly on MNX 9 to MNX 40 contactors.\"}}, {\"@type\": \"Question\", \"name\": \"Is this L\u0026T or Lauritz Knudsen?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"L\u0026T Switchgear became Lauritz Knudsen (LK) in 2024, so this is the same MN relay range under the LK name. Units may carry either name depending on stock.\"}}, {\"@type\": \"Question\", \"name\": \"Do you provide a GST invoice?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Every order comes with a GST invoice.\"}}]}\u003c\/script\u003e\n\u003c\/div\u003e\n","brand":"L\u0026T\/ LK","offers":[{"title":"Default Title","offer_id":50598881361977,"sku":"SS94141OOSO","price":2780.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0597\/0922\/7065\/files\/lk-l-and-t-mn2-overload-relay_54469f71-0f87-4592-872a-d35358aca097.webp?v=1793552594","url":"https:\/\/voltkart.in\/products\/lk-mn-2-thermal-overload-relay-3-5a","provider":"Voltkart","version":"1.0","type":"link"}